Hebei Yingnai Environmental Protection Technology Co., Ltd.
Hebei Yingnai Environmental Protection Technology Co., Ltd.
Contact

FRP Sleeve

Yingnai FRP Sleeve provides corrosion-resistant protection, penetration and localized reinforcement for industrial piping systems. Its lightweight fiberglass construction can be used around carrier pipes, wall penetrations or repair areas without introducing metallic corrosion. Sleeve diameter, length, wall thickness, clearance, end configuration and resin system can be customized for installation and service requirements.

FRP Sleeve
FRP Sleeve
Get Free Quote

Specification of FRP Sleeve

ItemTypical Technical Specification
Product NameFRP Pipe Sleeve
Primary FunctionPipe protection, wall penetration, casing, localized repair or engineered sleeve connection
Typical Manufacturing RangeDN50–DN4000
Typical Sleeve Length300–2000 mm as a common fabricated range; longer sleeves can be produced
Service ClassificationNonpressure protective sleeve, penetration sleeve, repair sleeve or pressure-rated connecting sleeve
Dimension SymbolsNominal size DN, sleeve ID, outside diameter OD, length L, wall thickness t and annular clearance C
Annular ClearanceSelected for pipe installation tolerance, thermal movement, spacers, grout or sealing system
End ConfigurationPlain cut end, chamfered end, bell end, flanged end or laminated transition
Pressure RatingProtective sleeves are normally nonpressure; connecting sleeves may be designed to PN6, PN10 or PN16
Resin OptionsIsophthalic polyester, vinyl ester, novolac vinyl ester or epoxy resin
Structural ReinforcementFilament-wound or contact-molded glass reinforcement; local strengthening at penetrations or anchor rings
Optional Water-Stop RingIntegral or bonded FRP puddle flange / water-stop ring for wall penetrations
Optional SpacersFRP, polymer or elastomeric spacers for carrier-pipe centering and separation
Repair ConfigurationSplit sleeve, bonded sleeve or externally laminated reinforcement sleeve
Manufacturing MethodFilament winding, centrifugal casting, pultruded tube section or contact molding
InspectionID, OD, length, roundness, wall thickness, end squareness, fit-up clearance and laminate quality
Applicable StandardsASTM D6041, ASTM C582, ASME NM.2 and the project penetration or repair specification