| Item | Vertical FRP Storage Tank | Selection / Engineering Note |
| Product Name | Vertical FRP Storage Tank | Custom corrosion-resistant storage equipment |
| Typical Capacity Range | 0.1–160 m³ | Other dimensions can be engineered |
| Typical Diameter Range | D 400–4500 mm | Other dimensions can be engineered |
| Main Sizing Dimension | Tank body height L | See the three sizing-matrix sheets |
| Installation Orientation | Vertical, aboveground | Installation method depends on site and transport limits |
| Fabrication Method | Filament winding, contact molding or combined construction | Selected according to diameter, capacity and access |
| Structural Configuration | Inner corrosion barrier, structural laminate and outer protective layer | Laminate schedule is project-specific |
| Resin Options | Orthophthalic, isophthalic polyester, bisphenol-A vinyl ester, novolac vinyl ester or specified resin | Final resin must be checked against medium, concentration and temperature |
| Reinforcement | Surface veil, chopped-strand mat, woven roving and continuous glass roving | Glass type and content follow the laminate design |
| Design Pressure | Atmospheric as standard | Pressure or vacuum service requires a separate verified design |
| Operating Temperature | Designed according to resin system, medium and actual service conditions | Do not publish a single universal temperature limit without resin verification |
| Operating Medium | Water, wastewater, acids, alkalis, salts and selected process liquids | Chemical compatibility review is required |
| Design Specific Gravity | Project-specific; based on stored-liquid density | Customer should provide normal and maximum density |
| Corrosion Barrier | Resin-rich inner surface with chemical-resistant veil and laminate | Barrier thickness and resin are selected for the medium |
| External Protection | UV-resistant resin-rich layer, gel coat or project coating | Colour and protection system can be customized |
| Tank Bottom / Supports | Flat bottom, dished bottom or project-specific base | Foundation reactions must be confirmed by final design |
| Inlet and Outlet | Diameter, location, flange standard and reinforcement customized | Piping loads should not be transferred directly to the shell |
| Manhole | Size, quantity and location customized | Access and maintenance requirements govern arrangement |
| Vent / Overflow | Vent, overflow, vacuum breaker or emergency vent as required | Sizing follows filling, emptying and process conditions |
| Optional Accessories | Lifting lugs, ladder, platform, level gauge, baffles, supports and labels | Accessory loads must be included in structural design |
| Inspection and Testing | Raw-material check, visual inspection, dimensional inspection, laminate thickness, Barcol hardness and hydrostatic/leak test as specified | Test scope follows contract and applicable code |
| Applicable References | ASTM D3299; ASTM C582; ASTM C581; ASME RTP-1 where specified | Reference does not imply certification unless contractually stated |
| Installation Method | Foundation-supported or skid-mounted installation | Installation manual and lifting plan should be project-specific |
| Application Fields | Chemical processing, water treatment, food processing, pharmaceutical, electronics and general industrial storage | Actual suitability depends on medium and hygiene requirements |
| Customization | Capacity, diameter, height, resin, colour, nozzle layout, internals and support | Manufacture according to approved drawings |
| Required Inquiry Data | Medium, concentration, temperature, density, capacity, site, nozzle list and standard | These inputs are required before final quotation and design |