Hebei Yingnai Environmental Protection Technology Co., Ltd.
Hebei Yingnai Environmental Protection Technology Co., Ltd.
Contact

FRP Flue Duct

Yingnai frp flue duct is designed for wet, corrosive flue gas produced by boilers, scrubbers, desulfurization systems and industrial process equipment. Large-diameter fiberglass construction combines corrosion resistance with relatively low structural weight. Duct diameter, span, resin system, reinforcement, supports, expansion joints and connections can be engineered according to gas chemistry, temperature and pressure conditions.

FRP Flue Duct
FRP Flue Duct
Get Free Quote

Specification of FRP Flue Duct

ItemReference Specification
Product FamilyFRP Stack, FRP Chimney Liner and FRP Flue Duct
Stack TypesSelf-supporting, guyed, tower-supported, sleeve-type and multi-flue FRP stacks
Geometric LimitsSelf-supporting: height<30 m and H/D <10; guyed: height <45 m and H/D <20; tower-supported, sleeve-type and multi-flue: H/D <10
ConstructionCorrosion-resistant inner laminate, structural laminate and external protective/weathering layer
Resin OptionsVinyl ester, novolac vinyl ester, isophthalic polyester or project-qualified resin
Design TemperatureProject-specific; normal, maximum, upset and start-up temperatures shall be specified
Gas ChemistryState moisture, SOx, chlorides, fluorides, acid mist, oxygen, particulate, condensate chemistry and cleaning chemicals
Pressure / VacuumProject-specific; include fan pressure, draft, transient pressure and blocked-flow/vacuum cases
Structural LoadsDead load, wind, seismic, thermal gradient, internal pressure/vacuum, platform loads, attached duct loads, vibration and erection loads
Support ArrangementIntegral base, guy wires, external tower, outer shell or multi-flue support frame depending on stack type
Flue Duct GeometryCircular or rectangular cross-section; diameter/section and span are determined by airflow, velocity, pressure loss and structural support spacing
Joint OptionsShop-laminated or field-laminated joints, flanges and expansion joints selected for pressure, temperature and movement
AccessoriesPlatforms, ladders, inspection ports, drains, expansion joints, dampers, spray nozzles, supports, lightning protection and static-control provisions as required
Inspection and TestingMaterial certification, laminate inspection, Barcol hardness/cure checks, dimensional/alignment inspection, field-joint inspection and leak testing as specified
Applicable ReferencesASTM D3982-21 for contact-molded FRP ducts; ASTM D5364-14(2024) for FRP chimney liners with coal-fired units; project structural, wind, seismic and fire requirements
Required Inquiry DataGas composition, moisture/condensation, normal and upset temperature, flow rate, pressure/vacuum, diameter, height/length, support type, wind/seismic data, platform loads and site erection constraints
Design Limitationheight and H/D values are product-range references, not a substitute for project-specific structural design

FRP Stack and Flue Duct Reference Data
ProductHeight LimitH/D LimitSupport ArrangementEngineering Note
Self-Supporting FRP Stack< 30 m< 10Integral base / foundation supportfinal wind, seismic and buckling design required
Guyed FRP Stack< 45 m< 20Guy-wire stabilizedGuy arrangement, anchors and vibration control are project-specific
Tower-Supported FRP StackProject-specific< 10External steel or FRP support towerSupport reactions and thermal movement require coordinated design
Sleeve-Type FRP StackProject-specific< 10FRP stack/liner within an outer supporting shellTerm follows brochure; project configuration should be confirmed
Multi-Flue FRP StackProject-specific< 10Multiple FRP flues within common support systemEach flue and common support frame require separate load checks
FRP Flue Duct Selection Parameters
ItemReference Specification
Product NameFRP Flue Duct / Corrosive Gas Duct
ConstructionCorrosion-resistant liner, structural laminate and external protective layer
Resin SystemVinyl ester, novolac vinyl ester, isophthalic polyester or project-specified resin
Diameter / Cross SectionCircular or rectangular; customized by airflow and pressure-loss calculation
Design Pressure / VacuumProject-specific; verify positive pressure, vacuum and transient load cases
Operating TemperatureProject-specific and resin-dependent; continuous and upset temperatures shall be stated separately
Gas CompositionSOx, chlorides, acid mist, wet flue gas, particulate and other process-gas constituents
Joint TypeButt-and-wrap laminated joint, flanged joint or project-specific expansion joint
Support SystemSteel/FRP saddles, hangers, frames or tower supports with thermal-movement allowance
Optional AccessoriesExpansion joints, drains, inspection ports, spray nozzles, dampers, supports and grounding provisions