Yingnai FRP Diesel Fuel Tanks are designed for project-specific storage of diesel where the selected resin system is chemically compatible with the fuel. Corrosion-resistant composite construction reduces rust-related maintenance and can be configured for aboveground or underground installation. Capacity, connections, reinforcement, monitoring provisions and containment features are customized to operating and regulatory requirements.

FRP Diesel Fuel Tank
FRP Diesel Fuel Tank
Get Free Quote

Specification of FRP Diesel Fuel Tank

ItemVertical FRP Storage TankSelection / Engineering Note
Product NameVertical FRP Storage TankCustom corrosion-resistant storage equipment
Typical Capacity Range0.1–160 m³Other dimensions can be engineered
Typical Diameter RangeD 400–4500 mmOther dimensions can be engineered
Main Sizing DimensionTank body height LSee the three sizing-matrix sheets
Installation OrientationVertical, abovegroundInstallation method depends on site and transport limits
Fabrication MethodFilament winding, contact molding or combined constructionSelected according to diameter, capacity and access
Structural ConfigurationInner corrosion barrier, structural laminate and outer protective layerLaminate schedule is project-specific
Resin OptionsOrthophthalic, isophthalic polyester, bisphenol-A vinyl ester, novolac vinyl ester or specified resinFinal resin must be checked against medium, concentration and temperature
ReinforcementSurface veil, chopped-strand mat, woven roving and continuous glass rovingGlass type and content follow the laminate design
Design PressureAtmospheric as standardPressure or vacuum service requires a separate verified design
Operating TemperatureDesigned according to resin system, medium and actual service conditionsDo not publish a single universal temperature limit without resin verification
Operating MediumWater, wastewater, acids, alkalis, salts and selected process liquidsChemical compatibility review is required
Design Specific GravityProject-specific; based on stored-liquid densityCustomer should provide normal and maximum density
Corrosion BarrierResin-rich inner surface with chemical-resistant veil and laminateBarrier thickness and resin are selected for the medium
External ProtectionUV-resistant resin-rich layer, gel coat or project coatingColour and protection system can be customized
Tank Bottom / SupportsFlat bottom, dished bottom or project-specific baseFoundation reactions must be confirmed by final design
Inlet and OutletDiameter, location, flange standard and reinforcement customizedPiping loads should not be transferred directly to the shell
ManholeSize, quantity and location customizedAccess and maintenance requirements govern arrangement
Vent / OverflowVent, overflow, vacuum breaker or emergency vent as requiredSizing follows filling, emptying and process conditions
Optional AccessoriesLifting lugs, ladder, platform, level gauge, baffles, supports and labelsAccessory loads must be included in structural design
Inspection and TestingRaw-material check, visual inspection, dimensional inspection, laminate thickness, Barcol hardness and hydrostatic/leak test as specifiedTest scope follows contract and applicable code
Applicable ReferencesASTM D3299; ASTM C582; ASTM C581; ASME RTP-1 where specifiedReference does not imply certification unless contractually stated
Installation MethodFoundation-supported or skid-mounted installationInstallation manual and lifting plan should be project-specific
Application FieldsChemical processing, water treatment, food processing, pharmaceutical, electronics and general industrial storageActual suitability depends on medium and hygiene requirements
CustomizationCapacity, diameter, height, resin, colour, nozzle layout, internals and supportManufacture according to approved drawings
Required Inquiry DataMedium, concentration, temperature, density, capacity, site, nozzle list and standardThese inputs are required before final quotation and design

Standard Range A: 0.1–25 m³
CapacityD 400 mmD 600 mmD 800 mmD 1000 mmD 1200 mmD 1400 mmD 1500 mmD 1600 mmD 1800 mmD 2000 mmD 2200 mm
0.1850430








0.21650780490







0.5
18401090740






1

20801380






2


265018901440




3



278020901850



4



3660298024102150


5




355029802650


6





35503140


7






36402930

8






41003320

9






463037103060
10






513041003370
11






5630450036903100
12







489040103370
15







609049704150
18







725059204940
20







803065605470
25








81506790
Matrix values = L, tank body height (mm)
Standard Range B: 30–160 m³
CapacityD 2200 mmD 2400 mmD 2500 mmD 2600 mmD 2800 mmD 3000 mmD 3200 mmD 3400 mmD 3500 mmD 3600 mmD 3800 mmD 4000 mmD 4200 mmD 4500 mm
3081006860634058905130453040303620





35
796073606830594052404650417039803770



40
9070838077806750594052804720448042603880


45

940087207570665059005270500047604320


50


966083807360652058305520525047604320

55



91908070714063806040574052004750

60



100008770776069306560623056405140

65




9480838074807080672060805540

70




10190901080307600721065205940

75





963085808120770069606340

80





102529130864081907410673061005410
90






9680968091808090753068306040
95






102301020096708730793071906360
100








101619170833075506670
110









10050912082807300
120










992090007930
130










1071097208560
140










11510104409190
150










12310111609820
160











1190010440
Matrix values = L, tank body height (mm)